Select your language

EZDD/EZDS Heat Pump Electric Air Conditioner Series

Full DC variable frequency pure electric A/C, suitable for 6-13m pure electric, hybrid and fuel cell buses.

  • double-return air overhead unit

    Structure type

  • 28000-38000 kal/h

    Cooling capacity

  • 11000-36000 kal/h

    Heating capacity

  • R1407C

    Refrigerant

Technical Parameters

www.lingdaima.com(零代码excel转HTML)
Model EZDD-04 EZDS-04 EZDS-05 EZDS-06 EZDS-07
Cooling capacity (kcal/h) 13000 24000 28000 32000 38000
Heating capacity (kcal/h) 11000 22000 26000 30000 36000
HV Platform(V) 400-750 400-750 400-750 400-750 400-750
LV Platform(V) 24 24 24 24 24
Evaporation air volume (m³/h) 4000(4pcs) 4000(4pcs) 6000(6pcs) 6000(6pcs) 8000(8pcs)
Condensing air volume (m³/h) 6000(3pcs) 8000(4pcs) 8000(4pcs) 10000(5pcs) 10000(5pcs)
Refrigerant R407C R407C R407C R407C R407C
Weight (kg) 180 245 285 315 335
Dimension (mm) LxWxH 2700*1630*240 2500*1920*285 2750*1920*285 3000*1920*285 3250*2000*265
Application 6-7m 8-9m 9-10m 10-12m 13m
Unfold

Features

Reliable

The components shall meet the protection grade of IP67, dustproof and waterproof, and be free from damage by soaking.

Quiet

V-shaped shock absorption and noise reduction structure, low noise comfort environment.

Lower Consumption & Comfortable

The PWM stepless speed regulating coupling electronic expansion valve is precisely adjusted, with natural temperature transition and energy saving and comfort.

photos

Contact Us

Please feel free to send us your inquiries and we will give you a reply within 24 hours.

Get a quote

Please feel free to send us your inquiries and we will give you a reply within 24 hours.